Structure Description WDS Structure: 1--- Pump Body 2--- Nut of Impeller 3--- Anti-loose
Gasket 4--- Seal Ring 5--- Impeller 6--- Connection Frame 7--- Key
8--- Mechanical Seal 9--- Motor 10--- Base-plate Reliable Operation
and Convenient Maintenance The rigidity of shaft is good, for long
term operation, the accident probability of pump is very few. The
grease is used to lubricating the bearing,so it is convenient to
maintain. Due to the adoption of the structure with back opening
door, so the pipe neednt dismantling, the impeller and mechanical
seal can be dismantled or replaced.Mechanical Seal and No leakage
The mechanical seal is used for the gland seal of pump, so the
consumption of power is very low, the seal is reliable and no
leakage. The high quality seal can keep the pump to run more than
12000 hours. Light Weight, Less Occupying Land and Convenient
Installation The most compact structure is adopted in the design of
pump, so the weight of pump is light and the land occupied by pump
is small. It is very convenient to move or install, especially it
is suitable for the high building or the process flow. Application Construction Engineering Circulation of liquid, the heating water
in the center heat supply, ventilation and air-conditioning system,
the cooling water, the circulation of cooling , water supply,
boosting pressure, fire-fighting and the water circulation of
swimming pool as well as the water supply and drainage of the other
engineering.Industry The conditioning water, the transportation of
condensate water and the feed water of boiler in papermaking and
refine sugar industry,iron and steel manufacturing, petrochemical
industry and generating plant.Environment Engineering The filter
installation, water treatment system, dusts collecting
installation,re-cooling system, and sewer installation of polluted
water as well as sewage treatment. Water Supply The water supply
and water distribution, the boosting pressure in the waterworks and
the pump station, the man-made fountain or irrigation, the drip
irrigation and the irrigation & drainage in farm. Pumped Liquid The clean water free from the solid particulate, the solution in
chemical industry, the petroleum products and the other similar
liquids. Scope of Application Flow Capacity: Maximum 1000m3/h Head: Maximum 133m Temperature of
Liquid: -50 ---- +150(for details, please consult with the local
agent) For the standard pump: < 80 Working Pressure: 1.6MPa/
2.5Mpa Series sign WDS 125 100 200 (A) A R WDS- Series name 125- Dimension of inlet
(mm) 100- Dimension of outlet (mm) 200- Nominal dimension of
impeller (mm) (A)- Flow grade signal A- Impeller cutting number
(indicate with A, B, C,) R- High temperature type (working t
>80150) Installation Attachments Flexible installation foundation Rigid installation foundation
Concrete damping base Flange General WDS series horizontal centrifugal pumps have the most outstanding
hydraulic performance, the beautiful outline design and the most
perfect structure coordination. By utilizing many high scientific
methods and the advanced inspection means, WDS type pumps have the
unique advantage.Excellent Performance and High Efficiency The
advantage of WDS pump comes from the wisdom of many pump experts
and gathering the essence of the hydraulic models. There is no hump
on the performance curve of pump. Within the scope of wide flow
capacity, the pumps can run smooth without disturbing, have high
efficiency and lower cavitation.Smooth Running and Low Noise The
new driving pattern is adopted in the design of pump, that is, the
extended shaft directly drives the impeller. The rotor support
parts in the common centrifugal pump are cancelled.No needs
coupling. In additional to the elaborating rotor parts, the
impeller and the motor use the same shaft to run, so that the
smooth operation,less vibration and low noise of pump can be
guaranteed. Technical Characteristic(look table) Installation Size
If need, please contact us. E-mail:lseeechina@l6 |